This articles details the information on the knowledge base release of MCC for the month of June 2020.
MCC
|
- Changed overload type default from Bimetal Ambient Compensated to ESP200.
|
- Added solid state Sensitrip IV breakers with Advanced ETU Type, Dynamic Arc Flash System and abbreviations for Zone Selective Interlock options.
|
- Starters/Contactors MCC level default is now applied to all starters, not just VFD and RVSS.
|
- Starter/Contactor type now shows in the proposal, estimate sheet, and drawings.
|
- System voltage no longer has the word Delta for 3Ø3W on proposal and estimate sheet.
|
- Special pilot device abbreviation SD is no longer missing from abbreviation page.
|
- Added pricing for WL accessories Motor Operator Without Cutoff Switch, Plus Metering Function, Lock Brkr Off-Front Panel Mnt.
|
- Pricing is now being added for control terminal blocks when specified for mounting panel, special unit.
|
- Increased pricing for corner sections with Bus Bracing > 42,000 or Horizontal Bus Rating > 1600A.
|
- Unit diagrams D68500FDR, D68500MCB are now generated for feeders and MCB with aux contacts, alarm contact, shunt trip, undervoltage trip.
|
- Unit diagram D68600122 is now generated for FVNR with OFF pilot light and ON red pilot light.
|
- Added text UNIT to end of values for regional codes general specification when Regional codes <> None and ABS Certification = ABS With Unit Certification.
|
- Characteristic Total VA Calculation is now visible when Control power type = Unit CPT.
|
- When CPT sizing = specify the CPT VA is no longer restricted based on Total VA Calculation.
|
- Characteristic Top WW Mounting is now visible and user selectable for top MLO, MSPU, BDT units when unit sizing = specify.
|
- High density and SIERS units no longer allow 30MM blank pilot device housing.
|
- Added characteristics ABS Certification, Vessel Identification Number, Regional Codes, Arc Resistant, Arcing Duration, UL Labels, Certification, Customer Inspection, Witness Test to drawing details Layout tab.
|
- Characteristics Regional codes, ABS Certification, GENERAL TEXT9 are now populated in SAP.
|
- Changed Door Mod Code to Y for all 9810 digital meters.
|
- Unit Only dual units DFCB, DFDS, DFVNR, DFVC and Dual FVC MCC configuration are no longer missing PUCX code values on unit schedule.
|
- Dual unit only unit front view is now showing in layout for Order Engineering.
|
WL Breaker & Cradle
WL Breaker Configurator – Add 6000 A WL Breaker and Cradle for OEM sales
|
|
|
COMPAS Desktop & COMPAS GO – Configurator Breaker WL (for both the breaker and/or cradle)
|
UL TYPE = ANSI/UL1066 Drawout , Frame Amperage = 6000 Amp
|
Interrupting Rating Class H (85,000 AIC), L (100,000 AIC), M (150,000 AIC) at 254 & 508 VAC
|
Non-Automatic Interrupting Rating Class L available
|
|
Industry Mall – available July 1 – Configurators Breaker WL and Breaker Cradle WL
|
|
6000 A Cradle – New version – Standard Frame Size 3 cradle plus a Fan Kit to be mounted by the customer immediately below the cradle.
|
|