COMPAS KB Release Updates : June 2020 - Publish Sandy Articles
Sandy FAQ

COMPAS KB Release Updates : June 2020


This articles details the information on the knowledge base release of MCC for the month of June 2020.

MCC 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  • Changed overload type default from Bimetal Ambient Compensated to ESP200.
  • Added solid state Sensitrip IV breakers with Advanced ETU Type, Dynamic Arc Flash System and abbreviations for Zone Selective Interlock options.
  • Starters/Contactors MCC level default is now applied to all starters, not just VFD and RVSS.
  • Starter/Contactor type now shows in the proposal, estimate sheet, and drawings.
  • System voltage no longer has the word Delta for 3Ø3W on proposal and estimate sheet.
  • Special pilot device abbreviation SD is no longer missing from abbreviation page.
  • Added pricing for WL accessories Motor Operator Without Cutoff Switch, Plus Metering Function, Lock Brkr Off-Front Panel Mnt.
  • Pricing is now being added for control terminal blocks when specified for mounting panel, special unit.
  • Increased pricing for corner sections with Bus Bracing > 42,000 or Horizontal Bus Rating > 1600A.
  • Unit diagrams D68500FDR, D68500MCB are now generated for feeders and MCB with aux contacts, alarm contact, shunt trip, undervoltage trip.
  • Unit diagram D68600122 is now generated for FVNR with OFF pilot light and ON red pilot light.
  • Added text UNIT to end of values for regional codes general specification when Regional codes <> None and ABS Certification = ABS With Unit Certification.
  • Characteristic Total VA Calculation is now visible when Control power type = Unit CPT.
  • When CPT sizing = specify the CPT VA is no longer restricted based on Total VA Calculation.
  • Characteristic Top WW Mounting is now visible and user selectable for top MLO, MSPU, BDT units when unit sizing = specify.
  • High density and SIERS units no longer allow 30MM blank pilot device housing.
  • Added characteristics ABS Certification, Vessel Identification Number, Regional Codes, Arc Resistant, Arcing Duration, UL Labels, Certification, Customer Inspection, Witness Test to drawing details Layout tab.
  • Characteristics Regional codes, ABS Certification, GENERAL TEXT9 are now populated in SAP.
  • Changed Door Mod Code to Y for all 9810 digital meters.
  • Unit Only dual units DFCB, DFDS, DFVNR, DFVC and Dual FVC MCC configuration are no longer missing PUCX code values on unit schedule.
  • Dual unit only unit front view is now showing in layout for Order Engineering.

WL Breaker & Cradle

WL Breaker Configurator – Add 6000 A WL Breaker and Cradle for OEM sales

COMPAS Desktop & COMPAS GO – Configurator Breaker WL (for both the breaker and/or cradle)

UL TYPE = ANSI/UL1066 Drawout , Frame Amperage = 6000 Amp

Interrupting Rating Class H (85,000 AIC), L (100,000 AIC), M (150,000 AIC) at 254 & 508 VAC

Non-Automatic Interrupting Rating Class L available

Industry Mall – available July 1 – Configurators Breaker WL and Breaker Cradle WL

6000 A Cradle – New version – Standard Frame Size 3 cradle plus a Fan Kit to be mounted by the customer immediately below the cradle.