  • Added characteristic Assemble To Order for lead time complexity A4.

  • Changed reference order for unit only to default to PER COMPAS and added proposal and estimate sheet note.

  • Bimetal Ambient Compensated overload and overload heater tables on door are no longer selectable.

  • Added drawing note for ring tongue and fork tongue terminals.

  • Drawing Incoming spec second incoming data is now generated.

  • Solid state JD breaker now allows single alarm switch with 480 VAC configuration

  • Added standard wiring diagram for meter and SPD unit.

  • Standard wiring diagram D69052060 is now generated for high density FVNR size 1 with CPT and 2NO 2NC aux contacts and HOA switch.

  • MCC Unit Only shop unit notes line 1 and shop unit notes line 2 are now on separate lines in unit schedule just like MCC.

  • Can now configure MCB 110-125A ED breaker with copper lugs.

  • Unit schedule now showing trip option LSIG for FVNR, FVC, FVR, 2S1W, 2S2W, VFD, RVSS, RVAT, YDO, YDC.

  • Overload wraps are now set to 1 for SIMOCODE pro overload with heater/range sizing = standard so unit schedule always shows overload range.

  • When entering "Other" horsepower = 0.125, FVNR unit no longer becomes conflicted.

  • Auto layout of shipping split widths are no longer different for top incoming and bottom incoming.

  • Transducer characteristic Output is now required.

  • Group box description changed from AUXILIARY CONATCT to AUXILIARY CONTACT.

  • MCC Unit Only Arc Resistant restrictions for Telemand motor operator are now working.

  • Ground detection lights door mod code is now set to D only when common door top wire way = True.

.

Pricing Updates

  • Correct BPS, HCP & VBS pricing

MCCB

  • Add conflict when 150/250A (ND, HD, LD / NF, HF, LF) SS VL or 250A TM Sentron is selected

Technical

  • KB Version: 01.01.52.01

  • Price Version: 20200531

  • Release Date: 2/2021

.

  • VL SS type 150/250A Frame Breakers (ND, HD, LD, NF, HF, LF) trigs a conflict, use 3VA breakers

  • Panelboard P3, P4, P5 Pricing Updates

  • 3VA Breakers Drawing Issues Corrections (P1, P2, P3)

 .

Russelectric ATS

Digital Meter

  • Siemens Digital Meters now available to configure under Accessories section

SPD

  • Siemens TPS model Surge Protective Devices now available to configure under Accessories section

Russelectric LV/MV SWG

Digital Meter

  • Added catalog number field and rules to generate

Custom Component

  • New default set Installation Labor Hours to 0 to fix pricing key issue

Cubicle

  • Controls Only depth of 28.125” now available for selection

Auto Generated standard devices

  • Type & quantity of standard devices in auxiliary compartment based on cubicle updated per Russelectric spec documents

Reports

  • Wording of pricing keys updated per Russelectric spec documents

Russelectric SWG Mods

New Product

  • Should only be used by internal Russelectric users

Russelectric ATS Mods

New Product

  • Should only be used by internal Russelectric users

.

 

LVS / RCS - Added SEM3T and NEMA 3R Walk-in Outdoor Enclosure Redesign

SEM3T – Selections in Automation tab set default locations to be monitored:

  • Incoming

  • Load Connections

  • Power Connectors

Actual locations monitored can be selected / de-selected at the devices:

  • Line/Load Connection of WL Breakers

  • Bus Levels in Sections

  • A count of points monitored per section (3 per location) are shown in Section.  1 SEM3T controller is required per 45 points monitored.  Default controllers required will be set in section 1

NEMA 3R Walk-in Outdoor Enclosure was redesigned due to NEC code changes.  Some features of the redesign are a deeper Aisle (58”) and a new Front Roof.