This article consolidates all the answers to your questions in COMPAS Go.
[click on the "Expand All" button to view the answers for all the questions and click on "Collapse All" to collapse all the questions or click on the individual questions to the respective answer]
/
- We are requiring tech review anywhere a user uses a legacy FXD or DG where 3VA is a default this is in P3, P4, P5 panels and switchboards
- We have ensured 3VA41 is the most competitively priced breaker vs. xGB in P1
- To use FXD or DG, you will need to enter in a valid reason into the line items notes. If no reason is provided, the quote will be rejected
- If there is a reason to use xGB namely due to selective coordination, special pricing consideration can be considered with a pricing note or it can be placed in a P2
- 3VA41 (125A low tab/bolt on) is available P1
- 3VA52 (250A thermal magnetic breaker) is available in P3,P4,P5, SWBD
- 3VA53 (400A thermal magnetic breakers) is available in P1
- 3VA61 (150A electronic trip breaker) is available in P4,P5,SWBD
- 3VA63 (400A electronic trip breaker) is available in P1
- 3VA41 defaults in P1
- 3VA52 defaults in COMPAS when qty>=3 is selected on any 250A breaker selection
Yes, we are working to get the booklet updated with shipments, in addition they are attached here.
They are incorporated into the KB like other products. See example of how 3VA series ratings are incorporated
One of the easiest ways is to match the dropdown of the upstream breaker to the downstream panel
Ensure Downstream is selected to match UL type
Yes, updated booklet is being released in August, if you have a legacy booklet the updated booklet can be downloaded here - click here
Yes, 3VA41 breakers are available in UPB, they have been superseded P17 series with P18 and this version accepts 3VA41
Yes, as of the end of July 3VA TCCs are available from the major software including SKM, Easypower, ETAP and EasyTCC. If they are not part of the standard library yet, you can send a request to the vendor add 3VA to your library
- For Easy TCC go to the newest version
Yes, our latest Friday Lives are stored here - click here
- For field provisions with 3VA52, 62, 62 in P4, P5 and SWBD we had to add bus extensions to the breakers. The S3VA52PR kit will need to be ordered in addition to the breaker.
- For 3VA52 in a P3 Twin Mount – Hardware kit # BBKVA52P3HW is required in addition to the Breaker to add to an available provision.