COMPAS Go Release : October 2021


This articles details the information on the knowledge base releases for the month of October 2021. 

Switchboard

Panelboard

Russelectric

Siebreak


.


.

  Panelboard

.

3VA Breaker Updates

Series Rated Updates

  • 3VA series rated offer updates in Panelboard KB

  • Issue correction for series rated panels with 600A frame 3VA breakers

Sentron & VL Breakers Updates

Sentron ED Breakers Conflict

  • ED breakers conflict when ED breakers with no ground fault sensing kit option

  • ED breaker red conflict can be removed by unselecting Breaker Flag checkbox in Resolve Conflict 

P1 Unassembled Panelboard Updates 

  • Issue correction for P1 unassembled panelboard single phase system with 3VA52 main breaker

Panelboard KB Other Enhancements and Issues Corrections

  • Single mounted branch breaker lug direction change option (Invert option) is on breaker configuration UI screen now

  • Informational text note for ED type breaker with ground fault sensing kit option selected

 

  • KB rules updates for technical review

  • Series rated updates for non-3VA breakers

  • Correction of power panels 400A / 600A Sentron breaker kit height in drawing view

  • Correction of issue with some P3 30” wide enclosure custom front pricing

  • Correction of P2 panel multi-section panel layout issues

  • Correction of power panels neutral sensor compartment height with feed thru lug option

Technical Info

  • KB Version: 01.01.81.01

  • Pricing Version:  20210929

  • Release Date: 10/2021

.

Switchboard

.

Switchboard

  • Add BU Region cstic

  • Select CSA options based on BU Region

  • Add Drummondville to Plant routing

  • Show ‘CSA’ instead of ‘UL’ for Canada sections

WL

  • Default to draw-out mounting when hoist & track is selected

  • Correct FS1 selection error when branch + utility meter

  • Prevent ANSI-1066 WLs in 4-high section

MCCB

  • CDAE should be the default option before LDAE @ 100K / 480V

SMM/MMS

 

  • Prevent > 50A HHED6

XFMRs

  • Select type 442 XFMRs when seismic, instead of new type 443 XFMRs

Utility Metering

  • Correct issues with EUSERC door #s

  • Add Nfld Power & London Hydro, CA utilities

  • Add 30.88 & 35.88H doors for CA

  • Add C phase high leg support for PG&E

  • Pass utility amps to section level to support 1000A EUSERC utility rules

Drawings

  • Correct front view busway symbol when inverted main or branch to show correct top or bottom position

  • Remove extra line when 2500A EUSERC pull with full-length thru bus

Technical Info

  • KB Version: 01.01.58.01

  • Price Version: 20190111

  • Release Date: 10/2021

.

Russelectric

.

Russelectric ATS

Pullbox

  • Changed pullbox selection from checkbox to drop down with options for location in reference to the transfer switch. Available locations are Top, Left, & Right

4X Enclosure Rating

  • Differentiated selections for 4X 304 stainless steel & 4X 316 stainless steel

  • Added corresponding catalog digits for each 4X type

Russelectric LV/MV SWG

      Add accessories to breaker compartment (MV SWG only)

  • Made “+Options” available in UI for breaker compartment types which allows user to configure accessory components

Russelectric SWG Mods

Modkit

  • Protective Relay Upgrade modkit type added

 

Release Info

  • KB Version: Russelectric ATS [00.00.08.02], Russelectric ATS Mods [00.00.08.02], Russelectric LV/MV SWG [00.00.06.01], Russelectric SWG Mods [00.00.07.01]

  • Pricing Version:  20210910

  • Release Date: 10/2021

.

  Siebreak

Quoting Ability for Auxiliary Units & Complete Metering Units

  • Options can be found in the auxiliary unit tab

  • Details/Options:

    • Unit type includes blank, cable pull, and transition units across 18W, 24W, and 36W

    • Includes a variety of device combinations of any size of Surge Arresters, VTs, CTs, and CPTs

      • Device limitations depend on unit type and size

      • **Please see chart on next slide for possibilities

  • Presence of VTs and/or CTs and/or CPTs will trigger LV Box in 36W sections
  • User will need to manually trigger on the adjacent 36W section for 18W or 24W

    • LV Box will automatically be triggered by the presence of VTs and/or CTs and/or CPTs in 36W units

      • **For 18W or 24W units that need a LV Box due to device selection, the user will have to manually trigger the checkbox on the adjacent 36W unit

    • Device graphics are shown on electrical one-line diagram

    • LV Box graphic is shown on mechanical drawing

Technical Info

  • KB Version: 00.00.00.23

  • Price Version: 20190111

 

  • Release Date: 10/2021