This article details the information on the features and bug fixes released as part of COMPAS knowledge base. Following are released for the month of April 2023.
.
3RE47
..
Breaker VL
|
- Price update only – Large Frame (800 – 1600 A) breakers & related Internal Accessories only
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
LH Contractor
.
|
Electrically Held & Mechanically Held:
|
|
- Edited rules for order lines for export (i.e. Siemens Canada) to allow all lines to ship as planned
|
|
- This issue appeared in the SAP order – no change will be noticed/required in the COMPAS or iMall order
|
|
|
|
Technical Info
|
|
|
|
|
|
|
MCCB
.
|
3VA53/63 400 Amp Breakers and 3VA54/64 600 Amp Frame, 400 Amp max Trip Amps:
|
|
- New Aluminum Body Lug – 3VA9373-0JJ24 (1) 250-750 KCMIL CU/AL or (2) 250 KCMIL CU/AL
|
|
|
|
3VA57/58/59 -1200/1600/2000 Amp Thermal Mag, Molded Case Switch (similar to Sentron ND/PD/RD) :
|
|
- Added 3 pole Frame Thermal Magnetic Trip Breakers
|
|
- Added 2 pole (in-3 pole) Frame Thermal Magnetic Trip Breakers for 3VA57 1200 Amp Frame
|
|
- Mounting Base – Front Connected or Rear Connected required 3VA58/59
|
|
- Able to select Internal Accessories (ST, UVR, Aux Contacts) and Lugs. Enclosures in a future release
|
|
|
|
3VA67/68/69 -1200/1600/2000 Amp Electronic Trip Breakers (similar to Sentron SND/SPD):
|
|
- Added 3 pole Electronic Trip Breakers
|
|
- Added 3 pole Electronic Trip Breakers – 100% Rated 3VA67/68
|
|
- Mounting Base – Front Connected or Rear Connected required 3VA68/69
|
|
- Able to select Internal Accessories (ST, UVR, Aux Contacts) and Lugs. Enclosures in a future release
|
|
|
|
3VA5/6 Thermal Mag, Molded Case Switch/Electronic Trip Breakers :
|
|
- A Rule Change implemented on existing quotes to fix lines with Enclosure Required = Yes
|
|
- In some cases, List Price was equal $0
|
|
- Re-open the configuration and Save & Close without making a change
|
|
- Check that Pricing may change.
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
Panelboard
.
|
- Special Front selection details added to drawings and proposal
|
|
- Issue with 100% rated box staying conflicted resolved
|
|
- Ability to configure a P3 panel with up to 12 3VA52 in a 30” W enclosure
|
|
- QP Breakers removed from being a selection as main breaker for Panelboards
|
|
- Corrected depth of PD890, PBD875, PBD890 to 14.50”
|
|
- Corrected depth of US2:WPS860R32, US2:WPS875R32, US2:WPS890R32, US2:WPS860R32, US2:WPS875R32, US2:WPS890R32 to 14.25”
|
|
- Move DAS selection and key interlock for 3VA to the top
|
|
- Fixed issue with Power meter compartment being mis-sized
|
|
- Conflict 32, 38" W P5 Panels with Sub feed and FTL selected
|
|
- Enable selection of (2) 400-750Kcmil CU/Al lugs for 3VA65 with 100% rated selected
|
|
- Conflict P2/P3 Panels with 750 KCMIL MLO/FTL selections made
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
Russelectric
.
|
Russelectric LV/MV/CNTRL SWG
|
|
- Added Siemens 19” and Siemens 22” screens
|
|
|
|
|
|
Russelectric SWG Mods
|
|
- Added Siemens 19” and Siemens 22” screens
|
|
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
SIEBREAK
.
|
- Fixed error that was resulting in no price key and no cost for Seismic Rating = HCAI (OSHPD) and Seismic
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
Switchboard
.
|
Canada
|
|
- Add CSA required selection
|
|
- Add VK/VB switches for CSA
|
|
- Add support for CSA label
|
|
|
|
MCCB:
|
|
- Add DAS side pan for individually mounted MCCBs with DAS only
|
|
- Add 1200-2000A individually mounted 3VA breakers
|
|
- Add 1200A 3VA panel mounted main design
|
|
- Correct drawing issue with vertically mounted 3VA main
|
|
- Correct drawing issues with 100/125A MCCBs
|
|
- Correct section width rules with 400A 3VA with SEM3
|
|
- Correct issue with 225A 3VA62/63
|
|
|
|
Section:
|
|
- Auto select density rated section bus when at least one 800-1200A panel 100% rated mounted device
|
|
- Prevent more than two 800-1200A 100% rated panel mounted devices per panel area
|
|
- Prevent 25W WL outdoor section with top lugs and top auxiliary compartment
|
|
|
|
Switchboard:
|
|
- Change OSHPD to HCAI (Health Care Access and Information)
|
|
- Add Panel Bus Rating selection – This will force distribution panel bus amperage to maximum available for the section, usually 3000A max.
|
|
|
|