COMPAS KB Release : July 2023

This article details the information on the features and bug fixes released as part of COMPAS knowledge base. Following are released for the month of July 2023. 

  • 3RE47   

  • 3WA   

  • MCCB  

  • Busway  

  • Panelboard  

  • PowerMod  

  • SieBreak  

  • Switchboard  

COMPAS Build Version : CM-P23.7.2 / CM-P23.7.2.1 / CM-P23.7.2.2


3RE47 Enclosed Soft Starter

.

3RE47 COMPAS – APPLICATION SELECTION ADDITION:

Technical Info

  • KB Version: 00.00.00.10 

  • Price Version: NA

  • Release Date: 07/2023

.


3WA

.

Breaker 3WA / Cradle 3WA COMPAS – INITIAL RELEASE

Technical Info

  • KB Version: 01.01.01.06 

  • Price Version: TBD

  • Release Date: 07/2023

.


MCCB.

Summary of changes in COMPAS – Molded Case Circuit Breaker

  • 3VA 1200 Amp Frames - Lugs

  • Aluminum Body Lugs –  (4) 1/0-500 KCMIL Cu/AL with Voltage tap is available 3VA9773-0JC43

  • 3VA55 800 Amp Frame with 800 Amp trip is available for the Motor Circuit Protector 

  • Typical   3VA5580-0MH36-0AA0

Technical Info

  • KB Version: 00.00.05.01 

  • Price Version: 20230701

  • Release Date: 07/2023


Busway.

  • Sentron 3/6 Bus Plugs: Add MG3 code for all configurations (VFP)

  • XJL Bus Plugs: Disable option for no factory installed breaker on XEC and XLEC types

Technical Info

  • KB Version: 00.00.49.01

  • Price Version: 20230701

  • Release Date: 07/2023


Panelboard.

  • Add selection to P1 panels to choose neutral bus material for hybrid RP1 interiors

  • Allow 415/240V for communication compartment in P2/P3.

  • Allow P2’s with vertical 3VA52, 3VA61,62 with unit space 39" for 74" high enclosure

  • Fix P2’s with vertical 3VA52, 3VA61,62 with unit space 33" for 68" high enclosure

  • Update drawing for 3VA53 main breaker to match subfeed breaker

  • Remove motor operator for 800-1200A 3VA breakers

  • Add (1)#14-1/0 CU/AL lug for 3VA52/61/62

  • Allow 3VA67 to have 100% rated at 1200A

  • Restrict 400 Hz BL breakers selection for Panelboards in COMPAS

  • 3VA41 subfeed breaker not showing in drawing

  • 3VA communications Enhancements

  • Generate a 6.25 kit in P5 when BL,BQD,ED breakers have an accessory

  • Show CED6 in drawing when used as main breaker

  • Prevent 800-1600A VL breakers on new configurations

  • Limit depth of P3 3R and 3R/12 enclosures to 7.75

Technical Info

  • KB Version: 01.01.95.01

  • Price Version: 20230705

  • Release Date: 07/2023


PowerMod.

  • PowerMod Lug Kit Updates have been implemented.

  • Access to all available Lug kits as a Field installable Accessory in the UI has been improved. All currently available Lug kits are now selectable per PowerMod Device as needed.

  • TapBox and Switches Configurations now allow for selecting complete list of available lug kits.

Note: Other improvements to the selectable Lug kits per specific PowerMod module type will be implemented as the 3VA Breaker modules are implemented for each family of products during the year.

Minor updates:

  • Jira CK-4212/new BTKB-63 is Complete:  Update Lug Kit KB

  • The UI is now available for users to select all available Lug Kits per PowerMod Module for Field installation.

  • Additions to Each Configurable Module family (WB, WBT, WEB) will be updated where necessary as the 3VA Breaker implementation Project is released in phases.  All other current PowerMod Modules that use Lug Kits have been reviewed and are up-to-date.

  • Jira CK-4211/new BTKB-39 is Complete:  Add (6) 750kcmil Lugs Kit to WB, WBM, WTB (and others as needed)

  • The UI is now available for users to select all available Lug Kits per PowerMod Module for Field installation.

Technical Info

  • KB Version: 00.00.27.01

  • Price Version: 20230701

  • Release Date: 07/28/2023


SieBreak.

  • Changes to Auxiliary KB

  • Changed “Transition Position” to “Auxiliary Position”

  • Cable Pull now specified as “Line” or “Load”

  • Added iSymbols on elec view for load-side cable pull

  • Fixes to Auxiliary KB

  • Added cable cutout for cable pull sections

Technical Info

  • KBVersion : 00.00.04.01

  • Price Version : 20221001

  • Release Date: 07/2023

.


Switchboard.

3VA:

  • External GF is selectable on 3VA, but not priced or selecting shunt trip (BTKB-168)

Devices:

  • Add PV selection to specify PV source device

MCCB:

  • Allow 1600/2000A 3VA to be configured as a branch combo section

  • Correct error where > 125A 3VA branches are not configurable in COMPAS Canada

  • Prevent 800-1600A VL breakers on new configurations

Section:

  • Remove 100% rated MCCB, ASI requirement on end-feed sections (keep on center-feed)

  • Correct front view cover lines for code charts 11-D-0394 & 11-D-0691

Switchboard:

  • Automatically select 11.125” front enclosure when quick connects are selected

  • Add PV Switchboard selection to identify PV lineups

WL Breaker:

  • KI & Padlock not showing on all drawing for all configurations

Utility Metering:

  • Add MS-4-9.0 for PS NM CT specification

  • Update Canada utility specification #s and door heights

VBS:

  • Correct issue where 400/600A individually mounted VBS not shown on front view drawing

Add new SB4 Switchboard class

  • MG3 = VD0

  • Product hierarchy = 562SIXXXX-CVHX0039

  • ATS 2000A and greater

  • Custom autothrowover

  • Sm@rtGear

  • Add new SB4 factory modification custom codes for

  • Custom PLC

  • Custom communications

  • SB4 Switchboard

Technical Info

  • KB Version: 01.01.70.01

  • Price Version: 20230701

  • Release Date: 07/28/2023



Article ID: 4879
Last updated: 21 Jul, 2023
Revision: 7
Releases / Announcements -> COMPAS KB Release : July 2023
https://sandy.compas.siemens-info.com/compas-kb-release-july-2023_4879.html