COMPAS KB Release : September 2024

This article details the information on the features and bug fixes released as part of COMPAS knowledge base. Following are released for the month of September 2024. 

  • Breaker MCCB 

  • Digital Meter  

  • LVS-RCS  

  • MCC 

  • Panelboard 

  • Russelectric  

  • Safety Switch 

  |||||||||||||||||||||| | | | | | | | | | | | | Build Version : CM_P24.5.1 | | | | | | | | | | | | |


Breaker MCCB.

  • 3VA52/53/54/55/57 - 250/400/600/800/1200 Amp Thermal Magnetic 2 pole Breakers:

  • FD/JD/LD/LMD/MD/ND - 250/400/600/800/1200 Amp Thermal Magnetic 2 pole Breakers:

A text note is added to indicate that these MCCB are built as ‘2 pole in a 3 pole’ frame.  

Select feature ‘Poles’ = ‘2’, Same dimensions as a 3 pole version.

Internal Accessories and External Accessories are available, same as 3 pole versions.

Main conductor connections = ‘Other connectors’ or ‘No connectors’ for 3VA5 frames

– Only a few lug kits are available for 2 pole breakers.  Use 3 pole kits.

  •  3 Pole GFCI 5 ma & GFPE 30 ma  15-100 Amp Breakers

  • CQD Product Family – Cable In/Cable Out Breakers :

New versions of these ground fault protection breakers are now released for sale and selection in the configurator.  

See the section ‘Application Requirements’ and select the checkbox for either ‘GFCI 5 ma’ for personal protection or

‘GFPE 30 ma’ for equipment protection (previously shown as ‘GFCI 30 ma’)

New ‘Breaker ID @ IR ’ types for 15-100 Amp  GFCI 5 ma : ‘HCQDPF @ 65 KA’

Typical Catalog Number BQ3100GFHH (Available to order in August 2024)

New ‘Breaker ID @ IR’ types for 15-100 Amp  GFPE 30 ma : ‘HCQDQE @ 65 KA’     

Typical Catalog Number BQ3100EGHH (Available to order in September 2024)

These new versions are available with the CQD internal and external accessories. An accessory pole can be added to the left side.

New enclosures CQDN1SL, CQDN1FL and CQDN3RL are available in this release.

  • 3VA63 Electronic Trip Circuit Breakers – Cable quantity for Installed Lugs

The 3VA6 electronic trip circuit breaker 3 Pole can be provided with factory-installed lugs. 

We corrected the cable quantity for these standard lugs.

Aluminum Mechanical Lug - #1 – 600 KCMIL Cu/AL wire range – (1) Cable per Lug (was (2))

If the customer needs (2) Cables per lug , then select ‘Main conductor connections ‘ = ‘ Other connectors’.  

Then select ‘Cables per Lug – Line Side’ or ‘Cables per Lug – Load Side’ = ‘2’ .  

Wire Range options are ‘2/0-600 KCMIL Cu/AL’   or ‘250 KCMIL Cu/AL’ (one size only) with or without a voltage tap.

  • Thermal Magnetic MCCB – Standard or ‘Naval’ rated – UL 489 Supplement SB

We are making it easier for users to select either standard or ‘Naval Rated’ Thermal Magnetic (TM ) breakers.

The feature Breaker ID @ IR will show only the values for either standard TM breakers or ‘Naval Rated’ TM breakers, not both.

The default value for Application Requirements – ‘UL 489 Supplement SB’ = blank – not specified.  

Breaker ID @ IR values show only the standard TM values.

See below for image when Application Requirements – ‘UL 489 Supplement SB’ = Yes.  

Breaker ID @ IR values show only the Naval versions.

  • 1 Pole GFCI 5 ma 15-30 Amp Breakers

BL Product Family – Bolt-On for Panelboards

QP Product Family – Plug-In for Load Centers

Corrected the ‘Breaker ID @ IR’ values for one pole GFCI breakers in the configurator.  

  • Technical Info:

KB Version: 00.00.08.01 

Price Version: 20240701

Release Date: 09/2024

.


Digital Meter.

.

  • Add new 9410 meter variants

  • New options for Power Meters: “9410-E” (Essential) and “9410-A” (Advanced) class

  • 9410 option will now show as “9410-S” (Standard class)

  • New Fiber Ethernet expansion module (948MFIBER) added for 9410s and 9810

  • 10M cable checkbox removed

  • Remove obsoleted meters

  • PAC3100, PAC3200, 9510-ADR, 9510, 9610, 9200, 9340, and 9360 removed

  • Technical Info

KB Version: 00.00.00.12 

Price Version: NA

Release Date: 09/2024

.


LVS-RCS.. .

.

Sm@rtGear IE Updates (BTKB-1145)

  • Industrial Edge default set to True when Sm@rtGear IE selected

  • New IE App – Compliance Assist

  • Enable IE Cloud Connector – Enterprise Portal - DSC

  • Defaults set to True when Industrial Edge is True:

    • IE apps – Predictive Temp, PQ Basic, Compliance Assist

    • IE Cloud Connector – Building X, Enterprise Portal – DSC

  • Remove rule that only 1 Cloud Connector can be selected at a time

Minor Enhancements and Bug Fixes

  • Added new Digital Meter PAC4220 (BTKB-927)

  • Fixed missing proposal lines for IPC HRG Feeder Modules & HRG Portable Clamp-on Detector (BTKB-1051)

  • Fixed bug for missing Mechanical View Breaker Text when a custom Trip Rating is entered (BTKB-1139)

Technical Info

  • KB Version: 00.00.57.01

  • Price Version: 20121101

  • Release Date: 9/2024

.


MCC.

.

  • Added Allen Bradley 2100 units.

  • Added GE 7700 as a common factory option.

  • Added voltage indicators and absence of voltage tester as common factory options.

  • Added AE technical review for FCB, HFCB, DFCB 125-600A frame Sentron breaker.

  • Added AE technical review for LG breaker.

  • Added characteristic Breaker Z-Options for 3WA.

  • Wire marker type and component nameplate characteristics are now visible in view configuration for old configurations prior to June 2024 KB release.

  • Wire marker type and component nameplate no longer change from Heat Shrink to Sleeve or from Engraved-adhesive, Engraved screw to Label Adhesive.

  • Starter NEMA size 2 1/2 is no longer selectable.

  • Changed list price for FCB, MCB, TCB breakers for 3VA52 subtracted 20% and for 3VA54, 3VA64 added 10%.

  • Changed Dual FDS unit height from 12 to 18.

  • Changed 6 inch high density FCB 15-30A trip so that no additional panel mounted components can be mounted in unit because of larger load terminal block.

  • Changed 12 inch 30-60A FDS so that maximum panel mounted components are 3 instead of 4 because of larger load terminal block.

  • Added note Clear space must be maintained in front, sides and above the arc resistant MCC. See MCC instruction guide for details.

  • No longer incorrectly generating conflict messages: Dynamic Arc Flash Sentry System requires ETU776 trip unit type.; Earth Fault Module & Summation CT amperage no longer available.; SIMOCODE pro overloads are not allowed in high density units which also contain a CPT.; Only ESP200 overloads are allowed on high density FVNR units.; Bimetal ambient compensated overload not available with bypass contactor.; An 18 pulse VFD is only allowed with a G120 VFD.; An 18 pulse VFD is only allowed with an E and F Frame G120 VFD.; many other 18 pulse messages; many other VFD PM250 messages.

Technical Info

  • KB Version: 00.00.63.01

  • Price Version: 20221001

  • Release Date: 9/2024

.


Panelboard 

.

  • HBLEB-GFCI & HBLFB-GFCI breakers now available to select in PBD Configurations

  • P5 BL 6.25” Kit breaker placement fix

  • Users can now select HBQDQE breaker in PBD configurations

  • Custom enclosures to not show dimensions in estimate sheet to prevent confusion

Technical Info

  • KB Version: 01.01.104.01

  • Price Version: 20231212

  • Release Date: 09/2024

.


Russelectric.

.

Russelectric ATS

  • Updated Production Complexity Values per Updates from Jerry Le on 8/5

  • Added ERMS Button to Enclosure Tab

  • Added Selections to System Information Tab when a 4000A bypass is selected, an additional pop up will appear near the bottom regarding the Configuration.  The field is entitled “Bypass Configuration – Front View”, with the default option to be “Bypass-left, ATS-right”, the second “ATS-left, Bypass-Right”.  No price impact for either selection. 

Bug fixes:

  • Accessories selection quick view not showing metering communication selection-fixed

Russelectric ATS Mods

  • RPTCS Upgrades pricing missing - fixed

Russelectric LV/MV/CNTRL SWG

  • Added Siemens PLC option to the Controller/OIP accessories screen

  • Cubicle adder selections added by cubicle type at the section level

    • Gen Main Isolation Breaker

    • Bus Duct

    • Cable Compartment Barrier

    • Bus Differential

    • Nonparallel Temp Gen

    • Generator Manufacturer

    • Panel Board

    • Cam Locks

Russelectric SWG Mods

  • Field Service Labor Hour outputs - fixed

Technical Info

  • KB Version: Russelectric ATS (00.00.30.01), Russelectric ATS Mods (00.00.30.01), Russelectric LV/MV/CNTRL SWG (00.00.25.01), Russelectric SWG Mods (00.00.21.01)

  • Release Date: 9/2024

.


Safety Switch.

  • Correction to the elevator controls switch report field:

  • Elevator Control, Non-Fusible > Elevator Control, Fusible 

Technical Info

  • KB Version: 00.00.04.03 

  • Price Version: NA

  • Release Date: 09/2024

.



Article ID: 4938
Last updated: 25 Sep, 2024
Revision: 11
Releases / Announcements -> COMPAS KB Release : September 2024