This articles details the information on the features and bug fixes released as part of COMPAS knowledge base. Following are released for the month of February 2022. 


Switchboard

MCCBs

  • Add 3VA handle extension selection & pricing

  • Prevent 3VA test device power supply when TD-300 selected

  • Update 400/600A load lug selections

  • Revise 3VA front view drawing to match cover plate design

  • Add conflict & tech review when non-3VA panel mounted 400/600A MCCB is selected

  • Prevent new configurations and add conflict during reconfiguration of quotes containing 150/250A VLs

  • Add 3VA ST voltage to the estimate sheet key description (CK-3642)

  • Remove ‘Legacy conflict’ when BU region = Canada

Switchboard

  • Update order routing for USS to E170

  • Add option code & lead time identifier for Russelectric ATS

  • Correct conflict when 70H WL tie section with auxiliary metering

  • Prevent 25W WL section when NYC code

 

  • Set minimum depth to 48” when hoist & track + Busway connections

  • Correct missing electrical view for 800A panel mounted HCP main

  • 11-D-0517 with Compression lugs should be SB3 (CK-704)

SMM

  • Prevent adding SMMs when utility is Seattle City & Light

Utility Metering

  • Allow GA Power @ 38W, with tech review required

  • Add front view drawing support for 30.88” & 35.88” H utility doors (Canadian utilities)

  • Correct issue with cold sequence utility drawings

  • Correct issue with load lugs not showing on utility electrical view

  • Change Canada utilities hinge side to right

Technical Info

  • KB Version: 01.01.61.01

  • Price Version: 20220101

  • Release Date: 2/2022

.

 Siebreak

NO TECH REVIEW:

  • LIS with MO switch

  • CPTs

  • CTs

  • VTs

  • SAs

  • Blown fuse indication (no shunt trip)

 

TECH REVIEW REQUIRED:

  • LIS with EO switch

  • LIS with shunt trip or shunt close

  • All VCB units

  • All Aux units

  • Any custom mods – at parent and/or child level

  • Line ups with 4 or more units

 

Additional Updates:

  • 3 kVA CPT option added for Rated Voltage of 5 kV [List price: $1810]

  • “Light and switch” checkbox is selected as default for NEMA 3R enclosure type

  • User can still manually choose to remove the selection

Technical Info

  • KB Version: 00.00.00.26

  • Price Version: 20220107

  • Release Date: 02/2022

.

MCC

MCC Updates

  • Added 125-250A 3VA circuit breaker to FCB units.

  • 600V MM440 VFD is no longer allowed.

  • 18 Pulse VFD is no longer allowed.

  • G120 PM240-2 VFD B frame with 2 contactors is now a unit height of 24 for CED breaker.

  • Added short circuit rating of 480V 100K for CED6 thermal magnetic breaker with size 4 heavy duty contactor.

  • Changing Assemble to Order from true to false no longer sets all pilot device quantities from 1 to blank.

  • Added Wiring Diagram value Special Unique and new characteristics Special Unique Unit Diagram 1 - 4.

Technical Info

  • KB Version: 00.00.54.01

  • Price Version: 20210608

  • Release Date: 2/2022

.

Components

Transformer

  • Updated to have Series F as the Default Series for 3F3Y 480:208Y 15-750 KVA , Aluminum Wound, Temperature Rise 80C/115C .  

  • Series A was the Default Series and is now an available alternative series for these versions.

Technical Info

  • KB version: 00.00.06.32

  • Price version: 20220101

  • Release Date: 2/2022

WL Breaker

  • Updated for the correct pricing key value for WL Breakers with a combination of Communication = PROFINET IO/MODBUS TCP (COM35) and Remote Close Switch 120VAC.

Technical Info

  • KB version: 00.00.00.29

  • Price version: 20220101

 

  • Release Date: 2/2022

Pumppanel/Pump Controllers

  • Dynamic Cut Sheets now available in COMPAS GO for TYZ:Pumppanel Class 83/84/87/88 with Factory Modifications.

Pump Controllers Class 83 & 84

  • NEMA 12/3/3R now meets NEMA 12/3/3R/4. NEMA 4 painted now obsolete.

  • Coil Description 120 VAC Separate Control changes to 120V 60 Hz/110 VAC 50 Hz

  • Coil Description 24 VAC Separate Control changes to 24V 50-60 Hz

  • Obsolete factory mod SC Surge Capacitor

  • Factory mods R22, R40, G22 updated from 3RH1 to 3RH2 versions

Pump Panel Class 87

  • Coil Description 120 VAC Separate Control changes to 120V 60 Hz/110 VAC 50 Hz

  • Coil Description 24 VAC Separate Control changes to 24V 50-60 Hz

  • Vacuum Contactor versions are now 600 VAC rated with a ‘6’ in the catalog number.   Previous versions were 480 VAC rated with a ‘4’ in the catalog number.   Please see the Speedfax or Industrial Catalog for more details.

  • Obsolete factory mod SC Surge Capacitor

  • Factory mods R22, R40, G22 updated from 3RH1 to 3RH2 versions

Pump Panel Class 88

  • Coil Description 120 VAC Separate Control changes to 120V 60 Hz/110 VAC 50 Hz

  • Coil Description 24 VAC Separate Control changes to 24V 50-60 Hz

  • Obsolete factory mod SC Surge Capacitor

  • Factory mods R22, R40, G22 updated from 3RH1 to 3RH2 versions

Technical Info

  • KB version: 00.00.10.16

  • Price version: 20220131

  • Release Date: 2/2022

.

Panelboard

Panelboard Updates

  • Implement 3VA55/65/66 lug restrictions for Skinny P5

  • Correct import issue in ECR for P4

  • Prevent VL DG/FG frames in new configurations and select tech review required for existing configurations

  • Correct issue where 3VA66 lug catalog number was not populating

  • Correct conflict when creating series rated configurations

  • Correct conflict when 3VA65 @ 800A with 100% rating

  • Add conflict message when 3VA66 with 100% rated

  • Correct issue with FTL position shifted up when configuring 3VA under split bus

Technical Info

  • KB Version: 01.01.84.01

  • Price Version: 20220101

  • Release Date: 2/2022

.

Russelectric

Russelectric ATS

Power Connections

  • 2P standard mechanical lug ranges added

Complexity

  • Show Engineering complexity at top of window. Changes dynamically with configuration selections

Switch Configuration

  • RPTCS controller enabled for manual operation switches

Russelectric ATS Mods

Complexity

  • Show Engineering complexity at top of window. Changes dynamically with configuration selections

Russelectric LV/MV SWG

WL Breaker

  • Fixed bug with Cradle catalog number not populating for some configurations

Comp. Breaker

  • 4P breaker pricing

System

  • Remove System Interrupt Rating and replaced with Bus rating

Technical Info

  • KB Version: Russelectric ATS [00.00.11.01], Russelectric ATS Mods [00.00.11.01], Russelectric LV/MV SWG [00.00.10.02], Russelectric SWG Mods [00.00.10.01]

  • Price Version: 20220101

  • Release Date: 02/2022