COMPAS KB Release : February 2023 - Publish Sandy Articles
Sandy FAQ

COMPAS KB Release : February 2023

This article details the information on the features and bug fixes released as part of COMPAS knowledge base. Following are released for the month of February 2022. 


Panelboard

  • Pricing updates for 800A Sentron/ VL breakers

  • Provide conflict message for vertical Main 3VA 250A breaker and an SPD in P3 Panel

  • Provide conflict message for 600A-3p 3VA54 selected as a horizontal mount in P2 Panel

  • Lead time added for MG/NG 800 and 1200A VL breakers

  • Provide a clear conflict message for P1 panel with 4X Non-Metallic and 4 with Enclosure Height IN (62, 68, 74, 80)

  • Add ASCO 920 to interior is custom so that appropriate bus bars can be added during flow through process

  • Do not allow unassembled PBD for NB Chassis with 208Y/120 3Ø 4W Wye AC

  • Provide Drive to type rules for Invalid configurations in P3 mains with 3VA subfeed breakers

  • Resolve issue when 100% rated is selected by making Lug material default to Copper for certain 3VA breakers

  • Provide clear Conflict message for P2 with 4X Non-Metallic, 4 Enclosure with height in (62, 68, 74, 80)

Technical Info

  • KB Version: 01.01.92.01

  • Price Version: 20230202

  • Release Date: 02/2023

.


Switchboard

BPS:

  • Remove tech review for DAS, except when solar viewing window required

Incoming:

  • Enhance rules to remove incorrect tech reviews when incoming/main amperage does not match

MCCB Breakers:

  • Add 20-day lead time adder when M-Frame VL is selected

  • Add 800/1000A individually mounted 3VA mains/branches

  • Add pricing for individually mounted 3VA with busway

  • Correct error where 3VA allowed more accessories than possible

  • Correct 3VA main + panel section unit space height

  • Remove legacy MCCB tech review when Sentron FD/JD/LD selected

  • Remove Modbus RTU automatic selection when 3VA with DAS

Switchboard:

  • Update Canadian channel sill heights to be visible when CSA Options is selected

  • Add TPS4 SPD for Canadian switchboards

  • Correct 800/1200A 100% rated section rules

  • Hide extra seismic 1.5 selection

  • Combine enclosure type & CA Enclosures into a single enclosure type selection

  • Correct ground bus drawing notes

  • Remove tech review when > 4000A

  • Show HRG on proposal document

  • Correct drawing text on 32W auxiliary compartment and SMM/MMS devices

  • Show shipping split information on switchboard drawing

WL:

  • Enable 800-1200A WL main for CSA

  • Remove SB3 rule when aux contacts added

  • Update pricing to indicate ST control power source

Utility Metering:

  • Remove OGE Energy Corp

  • Update Eugene WEB specification # & minimum section width

  • Add CT mounting type selection for Canadian utilities

  • Update Rochester Gas Elec specification #

  • Add Colton Electric Utility & SFPUC EUSERC utilities

  • Default SDG&E utility to cold sequence when 1200A or larger

  • Update drawing for CPS San Antonio & Entergy utilities

Technical Info

  • KB Version: 01.01.68.01

  • Price Version: 20220701

  • Release Date: 02/2023

.


LV Components

MCCB

  • 3VA53 Thermal Magnetic 400 Amp: Corrected wire range for factory-installed lugs #1 -600 KCMIL CU/AL

  • 3VA61-68 Electronic Trip Breakers : Added text note that 3VA61-3VA68 meet UL489 Supplement SB except not for 100% Rated Breaker.

  • 3VA55/65 800 Amp Breaker:  Corrected Neutral Kit HN678ACB for Type 1 & 3R enclosures

Technical Info

  • KB Version: 00.00.01.01 

  • Price Version: 20220701

  • Release Date: 02/2023

Soft Starter:

  • Enhancements to 3RE47 Soft starter configurator:

  • KB and UI update

  • K04 MOD Price update

Technical Info

  • KB Version: 00.00.00.05

  • Price Version: 20230202

  • Release Date: 2/2023

.


Transformer

  • Sentron Power Centers: Fixed KVA value for 22kva – now shows correctly at 22.5 kVA

  • Motor Drive Isolation: Fixed HP rating – was 7HP – now shows correctly at 7.5HP

  • Tap correction:  1000 kVA series was 3F3S000… now shows correctly as 3F3T000… for both Series J and H

Technical Info

  • KB Version: 00.00.06.34 

  • Price Version: 20220701

  • Release Date: 02/03/2023


Safety Switch

  • General Duty 30 Amp Fusible: Add (4) new 2 & 3 pole versions with Oversized Enclosures

Technical Info

  • KB Version: 00.00.00.16 

  • Price Version: 20220701

  • Release Date: 02/2023


Russelectric

Russelectric ATS

Reports

  • More detailed description for Annunciators including enclosure type & rating, voltage, etc.

Switch Options

  • Wall-mounted enclosure type not compatible with current limiting fuses on any source

Russelectric LV/MV/CNTRL SWG

Digital Meter

  • Rules from punchout KB now implemented to resolve missing defaults & limitations of options

Lineup Arrangement

  • Now able to click and drag cubicle instances to re-order the lineup

Technical Info

  • KB Version: Russelectric ATS (00.00.21.01), Russelectric LV/MV/CNTRL SWG(00.00.18.01) 

  • Price Version: 20220701

  • Release Date: 02/2023


Power Mod

  • New PowerMod WXBV 200A-600A are being launched (700A-1200A are pending)

          …N (85kA) and …NU (100kA) are being launched (32 new Mains)

  • The new 3VA Cross-Bus Main Devices will replace the previous series Sentron based WXB mains

          - Legacy WXB Mains will be available for printing layouts only – all new orders will be WXBV series.

  • The new 3VA based WXBV series is available in 85 kA and 100 kA only (3VA53 400A max. and 3VA54 600A max.)

  • - Users must change/select the 85 kA or 100 kA in order to get a list of available WXBV units. 65kA is only for Sentron WXB

  • When a WXB catalog is selected an error message will be shown advising to change to WXBV series.

  • There is a small difference in the Enclosure sizes – these are reflected in the layouts.

Minor updates:

  • Layout issue with Cross Bus Switch KB : The Value for “A7JPM_TAP_STACK_DISP “ was NOT set as “Required”.  This has been corrected and the default is set to “NONE”, but it now allows for the module to be included in layout properly.

Technical Info

  • KB Version: 00.00.25.01

  • Price Version: 20220701

  • Release Date: 02/2023


MCC

  • Added 3RW55 RVSS and made the 3RW55 the default RVSS starter for above 50HP.

  • Added 3VA breaker for size 1-6 SIRIUS starter units and made the SIRIUS contactor the default for starter units.

  • Added 3VA breaker for 400-600A frame FCB unit and 600V 150-250A frame FCB unit and made the 3VA breaker the default for the FCB unit.

  • Added standard wiring diagrams for PAC3120, PAC3220 meters.

  • Meter unit is now defaulting CPT sizing and setting CPT VA Size. The other miscellaneous units are now setting CPT VA size.

  • HE breaker is no longer available for feeders.

  • Added characteristic Panel Type to drawing details Layout tab for COMPAS OE config xml.

Technical Info

  • KB Version: 00.00.57.01

  • Price Version: 20221001

  • Release Date: 2/2023