This article details the information on the features and bug fixes released as part of COMPAS knowledge base. Following are released for the month of February 2022.
.
Panelboard
|
- Pricing updates for 800A Sentron/ VL breakers
|
|
- Provide conflict message for vertical Main 3VA 250A breaker and an SPD in P3 Panel
|
|
- Provide conflict message for 600A-3p 3VA54 selected as a horizontal mount in P2 Panel
|
|
- Lead time added for MG/NG 800 and 1200A VL breakers
|
|
- Provide a clear conflict message for P1 panel with 4X Non-Metallic and 4 with Enclosure Height IN (62, 68, 74, 80)
|
|
- Add ASCO 920 to interior is custom so that appropriate bus bars can be added during flow through process
|
|
- Do not allow unassembled PBD for NB Chassis with 208Y/120 3Ø 4W Wye AC
|
|
- Provide Drive to type rules for Invalid configurations in P3 mains with 3VA subfeed breakers
|
|
- Resolve issue when 100% rated is selected by making Lug material default to Copper for certain 3VA breakers
|
|
- Provide clear Conflict message for P2 with 4X Non-Metallic, 4 Enclosure with height in (62, 68, 74, 80)
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
Switchboard
|
BPS:
|
|
- Remove tech review for DAS, except when solar viewing window required
|
|
|
|
Incoming:
|
|
- Enhance rules to remove incorrect tech reviews when incoming/main amperage does not match
|
|
|
|
MCCB Breakers:
|
|
- Add 20-day lead time adder when M-Frame VL is selected
|
|
- Add 800/1000A individually mounted 3VA mains/branches
|
|
- Add pricing for individually mounted 3VA with busway
|
|
- Correct error where 3VA allowed more accessories than possible
|
|
- Correct 3VA main + panel section unit space height
|
|
- Remove legacy MCCB tech review when Sentron FD/JD/LD selected
|
|
- Remove Modbus RTU automatic selection when 3VA with DAS
|
|
|
|
Switchboard:
|
|
- Update Canadian channel sill heights to be visible when CSA Options is selected
|
|
- Add TPS4 SPD for Canadian switchboards
|
|
- Correct 800/1200A 100% rated section rules
|
|
- Hide extra seismic 1.5 selection
|
|
- Combine enclosure type & CA Enclosures into a single enclosure type selection
|
|
- Correct ground bus drawing notes
|
|
- Remove tech review when > 4000A
|
|
- Show HRG on proposal document
|
|
- Correct drawing text on 32W auxiliary compartment and SMM/MMS devices
|
|
- Show shipping split information on switchboard drawing
|
|
|
|
WL:
|
|
- Enable 800-1200A WL main for CSA
|
|
- Remove SB3 rule when aux contacts added
|
|
- Update pricing to indicate ST control power source
|
|
|
|
Utility Metering:
|
|
|
|
- Update Eugene WEB specification # & minimum section width
|
|
- Add CT mounting type selection for Canadian utilities
|
|
- Update Rochester Gas Elec specification #
|
|
- Add Colton Electric Utility & SFPUC EUSERC utilities
|
|
- Default SDG&E utility to cold sequence when 1200A or larger
|
|
- Update drawing for CPS San Antonio & Entergy utilities
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
LV Components
|
MCCB
|
|
- 3VA53 Thermal Magnetic 400 Amp: Corrected wire range for factory-installed lugs #1 -600 KCMIL CU/AL
|
|
- 3VA61-68 Electronic Trip Breakers : Added text note that 3VA61-3VA68 meet UL489 Supplement SB except not for 100% Rated Breaker.
|
|
- 3VA55/65 800 Amp Breaker: Corrected Neutral Kit HN678ACB for Type 1 & 3R enclosures
|
|
|
|
Technical Info
|
|
|
|
|
|
|
|
Soft Starter:
|
|
- Enhancements to 3RE47 Soft starter configurator:
|
|
|
|
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
Transformer
|
- Sentron Power Centers: Fixed KVA value for 22kva – now shows correctly at 22.5 kVA
|
|
- Motor Drive Isolation: Fixed HP rating – was 7HP – now shows correctly at 7.5HP
|
|
- Tap correction: 1000 kVA series was 3F3S000… now shows correctly as 3F3T000… for both Series J and H
|
|
|
|
Technical Info
|
|
|
|
|
|
|
Safety Switch
|
- General Duty 30 Amp Fusible: Add (4) new 2 & 3 pole versions with Oversized Enclosures
|
|
|
|
Technical Info
|
|
|
|
|
|
|
Russelectric
|
Russelectric ATS
|
|
Reports
|
|
- More detailed description for Annunciators including enclosure type & rating, voltage, etc.
|
|
|
|
Switch Options
|
|
- Wall-mounted enclosure type not compatible with current limiting fuses on any source
|
|
|
|
Russelectric LV/MV/CNTRL SWG
|
|
Digital Meter
|
|
- Rules from punchout KB now implemented to resolve missing defaults & limitations of options
|
|
|
|
Lineup Arrangement
|
|
- Now able to click and drag cubicle instances to re-order the lineup
|
|
|
|
Technical Info
|
|
- KB Version: Russelectric ATS (00.00.21.01), Russelectric LV/MV/CNTRL SWG(00.00.18.01)
|
|
|
|
|
Power Mod
|
- New PowerMod WXBV 200A-600A are being launched (700A-1200A are pending)
|
|
…N (85kA) and …NU (100kA) are being launched (32 new Mains)
|
|
|
|
- The new 3VA Cross-Bus Main Devices will replace the previous series Sentron based WXB mains
|
|
- Legacy WXB Mains will be available for printing layouts only – all new orders will be WXBV series.
|
|
|
|
- The new 3VA based WXBV series is available in 85 kA and 100 kA only (3VA53 400A max. and 3VA54 600A max.)
|
|
- - Users must change/select the 85 kA or 100 kA in order to get a list of available WXBV units. 65kA is only for Sentron WXB
|
|
|
|
- When a WXB catalog is selected an error message will be shown advising to change to WXBV series.
|
|
|
|
- There is a small difference in the Enclosure sizes – these are reflected in the layouts.
|
|
|
|
Minor updates:
|
|
- Layout issue with Cross Bus Switch KB : The Value for “A7JPM_TAP_STACK_DISP “ was NOT set as “Required”. This has been corrected and the default is set to “NONE”, but it now allows for the module to be included in layout properly.
|
|
|
|
Technical Info
|
|
|
|
|
|
|
MCC
|
- Added 3RW55 RVSS and made the 3RW55 the default RVSS starter for above 50HP.
|
|
- Added 3VA breaker for size 1-6 SIRIUS starter units and made the SIRIUS contactor the default for starter units.
|
|
- Added 3VA breaker for 400-600A frame FCB unit and 600V 150-250A frame FCB unit and made the 3VA breaker the default for the FCB unit.
|
|
- Added standard wiring diagrams for PAC3120, PAC3220 meters.
|
|
- Meter unit is now defaulting CPT sizing and setting CPT VA Size. The other miscellaneous units are now setting CPT VA size.
|
|
- HE breaker is no longer available for feeders.
|
|
- Added characteristic Panel Type to drawing details Layout tab for COMPAS OE config xml.
|
|
|
|