This article details the information on the features and bug fixes released as part of COMPAS knowledge base. Following are released for the month of February 2024.
|||||||||||||||||||||| | | | | | | | | | | | | Build Version : CM_P24.2.1 | | | | | | | | | | | | |
3WA.
.
|
- Addition of Option R23 – Withdrawable breaker without shutter
|
|
|
|
Technical Information
|
|
- 3WA KB Version: 01.01.01.08
|
|
- 3WA8 KB Version: 01.01.01.08
|
|
|
|
|
.
Loadcenter..
.
|
Load Center Updates – Misc text changes to the UI and defaults or rules established to allow for fewer clicks when configuring.
|
|
- Re-arranged order of selections.
|
|
- Enhanced actual displayed values to help make selections clearer.
|
|
- Enhanced some defaults and rules for easier selection.
|
|
- Added Hub Provision selection where needed to allow proper selection of devices.
|
|
- Revised Ground Bar % of Terminals to match current production.
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
LVS-RCS.. .
.
|
- Fixed import rule bug that was causing some selections to reset upon reconfiguration. (BTKB-650)
|
|
- Smartgear IE updates. (BTKB-727)
|
|
|
|
|
|
- Fixed 3WA cradle catalog number for Shutters (BTKB-702)
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
MCC.
.
|
- Added 3WA circuit breaker. Breaker accessories will need to be manually reselected if changing from WL to 3WA.
|
|
- Added AE technical review for 2500A horizontal bus for fan power on light.
|
|
- Unit widths 25, 45, 55 are no longer allowed.
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
Nema Contactor.
.
|
- Non-Reversing and Reversing Contactors - Class 40, 43 :
|
|
-
- NEMA Size 7 - Coil Code ‘S’ for 24VDC is no longer available.
|
|
-
- Mod M6 – Wattmeter – This mod is no longer available.
|
|
|
|
- No change in offering. We editted rules for which plant will build some products.
|
|
-
- Class 40 & 43 - NEMA Type 3R/4/12 and NEMA 4/4X Stainless Steel for NEMA Size 3-4
|
|
-
- Sales order child lines will appear as TYZ:ContactorCL40V, TYZ:ContactorCL43V
|
|
|
|
Technical Info
|
|
|
|
|
|
|
Panelboard.
|
- Added enclosure note to Panelboard drawing
|
|
- Allow users to select Alarm only for internal Ground Fault
|
|
- Allow users to select continuous industrial process for Ground Fault
|
|
- Updated unit space sizes for P5 with MLO compression lugs
|
|
|
|
- Remove Sensitrip Breakers from PB KB
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
PowerMod.
|
PowerMod Surge Protection Updates - See list below:(ref. BTKB-615)
|
|
- The ASCO TPS3 series and FirstSurge family of product is no longer available from the supplier.
|
|
- Existing orders for PMod product will be filled from stock or product previously ordered where possible.
|
|
- Changes for External Mount TPS3 and FirstSurge will be affective with the February release.
|
|
-
- The 4 current TPS3 “Type 1 - External mount” at 50000 Surge current for is being replaced by one TPS4 device. (TPS4A03050N = N-G connection included, but no dry contacts or external Indicator light)
|
|
-
- The 4 current TPS3 “Type 1 - External mount” at 100000 Surge current for is being replaced by one TPS4 device. (TPS4A0913D00 = N-G connection included, but no dry contacts or external Indicator light) (130k Surge current)
|
|
-
- “Type 2 - External Mount” are ordered the same way as before, but the child line will show the new Catalog #. (FS060 changes to FSPD060, FS100 changes to FSPD100, FS140 changes to FSPD140)
|
|
- Changes for Internal Mount TPS3 to TPS4 will not take effect until March or April release – pending PLM300 date.
|
|
- These are changing from “Factory installed” to “Field installed” SPD products to help with Supply chain issues.
|
|
|
|
- PowerMod WB and WEB additions - See list below:(ref. BTKB-681) - New 1140A variations are being introduced to stay below the 1200A DAS requirement.
|
|
- WB11140C, WB11140CU, WB31140C, WB31140CU
|
|
- WEB11140B, WEB11140BU, WEB31140B, WEB31140BU
|
|
|
|
- Enhanced or corrected some table values for Lug kits as needed:
|
|
-
- Lug kit tables were reviewed and updated in previous releases. A few additional “fixes” have been addressesd in this release where corrections were needed.
|
|
- “Center-Fed” Module Layout rules have been updated.
|
|
-
- PowerMod Cross-bus has a 1200A max. rating. Any device that allows more than 1200A on the Line side input is classified as a “Center-Fed” Module and must have “load type” modules on both the left and right side for the “Center-Fed” module. Devices like elbows, spacers and Surge modules, are NOT “load type” modules, and cannot be the only device on either side of the “Center-Fed” module. These issues have been addressed.
|
|
-
- WBM module types are now following the “Center-Fed” rules during layout.
|
|
-
- Note: It is up to the customer to balance the loading in any line-up. COMPAS does not have all the information/loading available to assist with “load balancing or limiting” on either side of the “Center-Fed” Module. Best practice would be to have a Cross-bus Main on both sides of the “Center-Fed” Module, but that is not a requirement.
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
Pump Panel.
|
- Pump Controller - Class 83, 84 :
|
|
-
- Mod M6 – Wattmeter – This mod is no longer available.
|
|
|
|
-
- Mods – add Meter Mods Ammeter M1, M2
|
|
-
- Mods – add Meter Mods Voltmeter M3, M4
|
|
-
- Mods – add Meter Mods Elapsed Time Meter M5
|
|
- Pump Panel - Class 82 : Obsolete – removed from the configurator
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
Russelectic.
|
Russelectric ATS
|
|
|
|
-
- More detailed description for Annunciators including enclosure type & rating, voltage, etc.
|
|
|
|
-
- Wall-mounted enclosure type not compatible with current limiting fuses on any source
|
|
|
|
Russelectric LV/MV/CNTRL SWG
|
|
|
|
-
- Rules from punchout KB now implemented to resolve missing defaults & limitations of options
|
|
|
|
-
- Now able to click and drag cubicle instances to re-order the lineup
|
|
|
|
Technical Info
|
|
- KB Version: Russelectric ATS [00.00.21.01], Russelectric ATS Mods [00.00.21.01], Russelectric LV/MV/CNTRL SWG [00.00.18.01]
|
|
|
|
|
Safety Switch.
|
- Heavy Duty 30 & 60 Amp Rated – Pyle National Receptacle in Stainless Steel enclosures - obsolete:
|
|
-
- Omit HF361SPN, HF362SPN, HNF361SPN, HNF362SPN, HF322JPN from the configurator
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
Soft Starter.
|
- Soft Starter Enclosed replaced by 3RE47 Soft Starter Enclosed.
|
|
- Favorites must be updated to the new version by clicking on the start icon.
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
Switchboard
|
3VA:
|
|
- 1E-406F - Update coverlines for 3VA thru mains (BTKB-339)
|
|
- 1E-461G - 3VA 800/1000A Inverted Assemblies (BTKB-359) (electrical view drawings will be update in April release)
|
|
- Twin mount 400A provisions should be 38W min (BTKB-488)
|
|
- Incorrect lug size on 15-40A 3VA41 (BTKB-354)
|
|
- 1200A 100% rated should allow -0JM43 lug (BTKB-354)
|
|
- 3VA61 should be selectable when CSA & cUL (BTKB-391)
|
|
- 3VA NS is being selected on 3W WYE systems (BTKB-365)
|
|
- Incorrect catalog # selected on #14-1/0 CU 3VA61 lugs (BTKB-393)
|
|
|
|
3WA Phase 3 updates (BTKB-625):
|
|
|
|
- Add automatic WL-3WA accessory conversion rules
|
|
|
|
- Remove portable test set option
|
|
- Enable 2500-5000A EUSERC utility with 3WA and load thru bus (BTKB-478)
|
|
- Remove (SB3) note for standard 3WA accessories
|
|
|
|
Auto layout:
|
|
- Panel mounted HCP main, should have incoming switch and thru bus in the same location (T/B) (BTKB-311)
|
|
|
|
Auxiliary section:
|
|
- Correct conflicts on Ameren bussed utility section (BTKB-311)
|
|
|
|
Customer metering :
|
|
- Prevent changing door insert type at compartment level
|
|
- Correct drawing issue when 25W and SPD only (BTKB-672)
|
|
|
|
Incoming:
|
|
- Default 3000-5000A PG&E incoming to busway (BTKB-247)
|
|
- Prevent top rear / bottom rear when inverted incoming is selected (BTKB-362)
|
|
- Update 5000A EUSERC pull with 14 positions to 48D min. (BTKB-391)
|
|
- Dominion Power incoming should default to lug provisions (BTKB-646)
|
|
|
|
Pricing:
|
|
- Canada neutral bonding not displaying in reports (BTKB-173)
|
|
- RE ATS in showing customer supplied and price for Siemens supplied (BTKB-259)
|
|
- $0 adder for NP screw types (BTKB-350)
|
|
- Adder required when any rear incoming is selected (BTKB-363)
|
|
|
|
Section:
|
|
- Strip heaters do not show wiring points in total WPs (BTKB-352)
|
|
- Assembly time updates from E250 (BTKB-623)
|
|
|
|
Switchboard:
|
|
- Add selection for NP screw types (BTKB-350)
|
|
- Enable Plant E480 For COMPAS / SAP Integration (BTKB-452)
|
|
- Update 5000A EUSERC pull with 14 positions to 48D min. (BTKB-391)
|
|
- Update SEM3 drawing when maximum # of spaces (BTKB-621)
|
|
- Dominion Power incoming should default to lug provisions (BTKB-646)
|
|
|
|
Technical Info
|
|
|
|
|
|
|
Transformer..
|
- Sentron Power Centers: Fixed KVA value for 22kva – now shows correctly at 22.5 kVA
|
|
- Motor Drive Isolation: Fixed HP rating – was 7HP – now shows correctly at 7.5HP
|
|
- Tap correction: 1000 kVA series was 3F3S000… now shows correctly as 3F3T000… for both Series J and H
|
|
|
|
Technical Info
|
|
|
|
|
|
|