Warning: preg_match_all(): Compilation failed: invalid UTF-8 string at offset 81 in D:\xampp\htdocs\client\inc\DocumentParser.php on line 262
COMPAS KB Release : November 2023 - Publish Sandy Articles
Sandy FAQ

COMPAS KB Release : November 2023

This article details the information on the features and bug fixes released as part of COMPAS knowledge base. Following are released for the month of November 2023. 

  • MCCB 

  • Russelectric 

  • Panelboard  

  • LH Contactor 

  • MCC 

  • Power Mod 

  • LVS-RCS 

  |||||||||||||||||||||| | | | | | | | | | | | | Build Version : CM_P23.11.1 | | | | | | | | | | | | |


MCCB.

  • Sentron ED/FD/JD/LD Telemand Motor Operators 

    • The electrical operators will continue to be provided as either 120 VAC or 240 VAC versions.

    • The 24 VDC, 48 VDC and 125 VDC versions are no longer available and are now obsolete. 

Technical Info

  • KB Version: 00.00.07.02 

  • Price Version: 20230701

  • Release Date: 11/2023


Russelectric.

.

Russelectric ATS

Standard Annunciator

  • New product roll out:

  • Standardized Remote Annunciator capable of displaying up to 8 RPTCS/RTSCD ATS units

  • Surface Mount, NEMA 1 and 4 rating

  • Accepts incoming voltage of 24VDC-250VDC or 80VAC-250VAC for Power Supply

  • Includes 7” HMI with a Graphical Overview Screen displaying equipment status, alarm status, power information, and enables users to perform transfer switch and generator testing

  • Setup configuration can be completed easily at the time of installation.

Drawing Documentation QR Codes

  • Added New drawing documentation option for QR Code to replace printed drawings being sent to customers upon product shipment.

Technical Info

  • KB Version: 00.00.24.01 

  • Price Version: 20230701

  • Release Date: 11/2023

.


Panelboard.. .

  • Added Seismic rating selection to Panelboard KB to match switchboards

  • Show branch connector material in drawing document as part of the options when it's AL/CU

  • Default 1000A breaker or larger as main to Solid state breaker

  • Add DAS by Default to 1200A main breaker

  • Add special fronts as part of the Front Selection option itself

  • Show lugs for VBS on drawing at the correct side

  • Ground fault protection to ETU relation fix

  • Ability to select ETU 360 FOR 3VA67 with internal GF

  • pricing keys fix to display fully and not partially

  • Show lugs for HJXD6 breaker in estimate sheet

  • Fix layout conflict with ED kit at 21"

Technical Info

  • KB Version: 01.01.97.01

  • Price Version: 20231105

  • Release Date: 11/2023

.


LH Contactor.

Electrically Held & Mechanically Held:

  • No change in offering.   We edited rules for which plant will build some products.

    • NEMA Type 3R/4/12 and NEMA 4/4X Stainless Steel for Contactor Amp Rating 60-200 Amp

    • Sales order child lines will appear as TYZ:ContactorLEV or TYZ:ContactorCLMV

  • Changes will appear in COMPAS, SAP and iMall quotes/orders.

Technical Info

  • KB Version: 00.00.09.33 

  • Price Version: 20230701

  • Release Date: 11/2023

.


MCC.

  • Added AE technical review for HD, LD, ND, HF, LF, NF 150-250A frame VL breakers.

  • Changed sensor amperage from 40 to 60 for 3VA61-EDAE CB. Now trip amperage goes down to 25A and is no longer red.

  • Changed MCC level unit default for starters/contactors from SIRIUS to heavy duty for models Model 95, Model 90, Marq21, Marq 2, Mark 1, Gould 5600.

  • Added system generated unit option abbreviation note to unit schedule drawing LG5 - STANDARD MECHANICAL LUGS ARE PROVIDED.

  •  Added ability for user to specify WL and 1600-2500A feeders as top or bottom fed using characteristic unit location.

  • 700HP 3RW55 RVSS CB no longer has red conflict for 50 wide. Changed panel type to recessed hat.

  • PLC with unit height 72 and unit width 40 and unit depth 18.713 no longer has red conflict.

  • FVNR SIRIUS size 1-2 with 3VA CB and SIMOCODE pro overload with 2 relays now allows additional unit space to be configured.

  • Changed vertical bus end Y for top 800-1200A MCB, FCB with additional unit space.

  • Added characteristics Entry Location, Unit Location to drawing details Layout tab for COMPAS OE config xml.

Technical Info

  • KB Version: 00.00.60.01

  • Price Version: 20221001

  • Release Date: 11/2023

.


Power Mod.

Misc. Corrections and/or updates to improve Customer Experience. - See list below:  (ref. BTKB-434)

  • The following KB's are impacted:

  • WML and WMK stacks

  • Elbows and Spacers

  • Cross Bus Main, Meter Combo and Tapboxes  

Minor updates:

  • Enhanced or corrected some image sizing or placement issues:

  • Some Gaps between modules were visually inaccurate.  Overall width calculations were not affected.

Technical Info

  • KB Version: 00.00.29.01

  • Price Version: 20220701

  • Release Date: 11/2023

.


LVS-RCS.

3WA:

  • Phase 1 release.  Frame size 2 and 3 3WA unfused breakers only.  Includes 3 and 4 pole.  Up to 100kAIC interrupt rating.

  • Frame size 1 3WA breaker will be added in a future release.

  • Breaker accessories will need to be manually reselected if changing from WL to 3WA.  Automatic breaker conversion rules to follow in future release.

  • Currently not available for use with arc resistant design, front connected LVS, HCAI (OSHPD) seismic rating, 6000A, or fused breakers.  These options will be added in future releases.

Enhanced Wireway

  • New selection for Wireway in Enclosure tab.

  • Enhanced selection gets the newly designed bigger top wireway trough.

  • Legacy selection gets the old style top wireway trough (if needed to match existing lineups).

  • To accommodate the larger wireway, some Integral Hoist modifications were required.  The new Enhanced and Legacy hoist designs are rated for 750 lbs, therefore the Static Switch hoist option is removed.

Technical Info

  • KB Version: 00.00.52.01

  • Price Version: 20121101

  • Release Date: 11/24/2023
This article was: