Warning: preg_match_all(): Compilation failed: invalid UTF-8 string at offset 81 in D:\xampp\htdocs\client\inc\DocumentParser.php on line 262
COMPAS KB Release : October 2024 - Publish Sandy Articles
Sandy FAQ

COMPAS KB Release : October 2024

This article details the information on the features and bug fixes released as part of COMPAS knowledge base. Following are released for the month of October 2024. 

  • 3WA  

  • MCCB  

  • LVS-RCS  

  • Manual Line 

  • Nema Contractor 

  • Panelboard 

  • Russelectric Products 

  • Switchboard 

  • Transformer 

  |||||||||||||||||||||| | | | | | | | | | | | | Build Version : CM_P24.9.1 | | | | | | | | | | | | |


3WA.

  • Added M71 Z-Option - Closing Coil/Shunt Trip without communication

Technical

  • KB Version: 01.01.01.10 

  • Price Version: NA

  • Release Date: 10/2024


MCCB..

3VA Circuit Breakers - External Accessories Phase 1

  • The following 3VA external accessories have been released for configuration:

  • Padlocking

  • Handle Blocking

  • Motor Operator

  • Telemand Motor Operator is now generalized to Motor Operator for the inclusion of 3VA

Note: These external accessories cannot be configured with an enclosure nor configured with each other

3VA6 Circuit Breakers – E Class with Enclosure

  • The 3VA6 Electronic Trip Circuit Breakers with the highest interruption ratings of 200,000 kA at 480V or 480Y/277V and 100,000 kA at 600 or 600Y/347V are now available in enclosures.

Technical

  • KB Version: 00.00.08.02 

  • Price Version: 20240701

  • Release Date: 10/2024


LVS-RCS.

    Added Restrictions / Conflict Messages

  • NEMA 3R Non Walk-In Enclosure (BTKB-1165)

  • No sections wider than 32”

  • No 6000A Breaker Section

  • Seismic

  • No sections wider than 40” (BTKB-1101)

Technical

  • KB Version: 00.00.58.01

  • Price Version: 20121101

  • Release Date: 10/2024


Manual Line.

  • Russelectric field service - 5 new lines were created to differentiate if field service lines need to meet prevailing wage requirements.

  • To select these prevailing wage lines – set Product family as ‘Russ Prev Wage Field Service’ and select appropriate purpose.

  • Based on purpose, configurator will add one of the manual line in the quote. It will behave same as existing field service manual lines.

Technical

  • KB Version: 00.00.19.03

  • Release Date: 10/2024


NEMA Contractor. Contractor

  • Made a correction for NEMA Contactor to set the default enclosure for NEMA 1 and NEMA 1 Extra Wide to the Clamshell version.

  • Wired Terminal Blocks are also available for NEMA Contactor as seen in the NEMA Starter release notes

Technical

  • KB Version: 00.00.09.26 

  • Price Version: 20240701

  • Release Date: 10/2024


Panelboard.

  • Display ETU type for 3VA66 breaker in estimate sheet

  • Resolved issue with QRH2 space not laying out correctly

  • Enhanced BOM Sales Report for SS branch and Thermal Mag Breakers

  • Auto provisions layout issue resolution

  • 3VA series rating updates

Technical

  • KB Version: 01.01.105.01

  • Price Version: 20231212

  • Release Date: 10/2024


Russelectric Products.

Russelectric ATS

  • Redline of Service Entrance in Same Cubicle for 03 & 30 Cycle Switches

  • Service entrance must now be in a separate cubicle in all 03 & 30 cycle switches until further notice, any existing quotes will need to be re-configured as such.

Technical

  • KB Version: 00.00.31.01

  • Price Version: 20241001​​

  • Release Date: 10/18/2024

Russelectric LV/MV/CNTRL SWG

  • Added helper cstics to support MFG KB

  • Cubicle adder selections added by cubicle type at the section level

  • Non-Standard Engine Interface

  • Added Engineering Labor Hour Calculations for Low Voltage Cubicles

  • Distribution

  • Generator Control

  • Utility Transfer Control

  • Transition

  • Utility Pull

  • Utility Metering

  • Generator Main Breaker

  • Generator Breaker

Technical

  • KB Version: 00.00.26.01

  • Price Version: 20241001​​

  • Release Date: 10/18/2024

Russelectric ATS Mods

Technical​

  • KB Version: 00.00.31.01

  • Price Version: 20241001​​

  • Release Date: 10/18/2024

Russelectric SWG Mods

Technical​

  • KB Version: 00.00.26.01

  • Price Version: 20241001​​

  • Release Date: 10/18/2024


Switchboard.

MCCB Breakers:

  • Prevent selecting both key interlock + padlock on the same 3VA device

  • Correct distribution panel section width when 100% rated 3VA64

  • Phase 1 of PV drawing indication

  • Prevent selection of SS Sentron breakers in Canada market

3WA/WL Breakers:

  • Add FS1 breakers

  • Default COM35 for WLs with Sm@rt

Autolayout

  • Place PV devices in bottom of panel area

  • Prevent auto creation of pull section when distribution panel section fed by transformer

CM Accessories:

  • Add 8 & 16 port SCALANCE switch selections

CM Digital:

  • Add 9410 fiber expansion module

Distribution Individual / Panel Mount:

  • Add FS1 3WA breakers

  • Add HD Combo 3WA sections

  • Update section width rules to prevent 32W with hinged gutter covers and IR windows

  • Add 3VA55/65/66 + EUSERC metering and load thru bus sections

Enclosure:

  • Add enclosure Type 1 + Dripshield for Canada market

  • Prevent above ground channel sills when NEMA 3R

Factory Mods:

  • Update catalog # and pricing for 8-port SCALANCE switch

Incoming:

  • Auto create pull section when 90C wireway or FP-MCCB selected for Canada market

Pull Section:

  • Auto create pull box when top feed EUSERC utility with incoming lugs or busway

  • Prevent EUSERC utility + lug landing in same section when 2500A or greater

  • Correct pull section dimensions for BC Hydro pull section

Section:

  • Update drawing to show thru bus when 4-High branch and bottom thru bus

  • Phase 1 of IR drawing indication

Series Ratings:

  • Add complete 3VA series ratings

Service Section:

  • Add FS1 3WA breaker support

Switchboard:

  • Correct error where factory modification not showing on proposal when added to incoming

  • Sm@rt gear updates – Add new Sm@rt IE options

  • Prevent DAS conflict when Sm@rt is selected

  • Updates to IR window selections and pricing

Utility Metering:

  • Correct Canada hydro compartments to show hinge on right side of door

  • Change Burlington Electric to use 1S-8500-17 standard specification

  • Remove Detroit Edison

VBS:

  • Remove obsolete switches, including 800 & 1200A

Technical

  • KB Version: 01.01.81.01

  • Price Version: 20240701

  • Release Date: 10/21/2024


Transformer.

  • COMPAS KB was missing many K-factors for misc System Voltage: issue #  (BTKB-1183)

  • Customers can now configure many additionak System Voltages with K4, K13 and K20 that were previously not selectable. 

  • Most configurations with K-Factors will not type match – so the MAP team will still need to provide Quotes, but at least the correct Catalog number will be available.

Technical

  • KB Version: 00.00.06.39 

  • Price Version: 20240101

  • Release Date: 10/2024

This article was: