This article details the information on the features and bug fixes released as part of COMPAS knowledge base. Following are released for the month of September 2023. 

  • MCCB  

  • PowerMod  

  • Panelboard  

  • Safety Switch  

  • Switchboard  

  |||||||||||||||||||||| | | | | | | | | | | | | Build Version : CM_P23.9.1 | | | | | | | | | | | | |


MCCB.

  • 3VA5  Thermal Magnetic Breakers – 100% Rated  now available:

The following Thermal Magnetic breakers are available as 100% Ampere Rated

                   ?   3VA52 40-225 Amp                       ?   40-175 Amp with Cu/AL cable                       ?   200, 225 Amp Cu cable only

                   ?   3VA53 200-400 Amp                     ?   200-350 Amp with Cu/AL cable                     ?   400 Amp Cu cable only

                   ?   3VA55 600-800 Amp                     ?   600, 700, 800 Amp with Cu/AL cable

                   ?   3VA57 800-1200 Amp                  ?    800-1200 Amp with Cu/AL cable

                   ?   3VA58 1400, 1600 Amp                ?   1400, 1600 Amp with Cu cable only

  • 3VA5  Thermal Magnetic Breakers & 3VA6 Electronic Trip Breakers – 100% Rated:  90 C Wire Rating 

When a 100% Rated breaker is selected the configurator now indicates if the conductors

for the Line and/or Load lugs must be 90 C insulated cable but sized to the 75C wire rating

ampacity tables in the National Electrical code.   This information is also marked on the breaker.

  • 3VA55 800 Amp Frame Motor Circuit Protector 

Updated the System Voltage for CMAP versions to be 600Y/347 V AC instead of 600 V AC. 

  • BL Product Family – 400 Hz Application now obsolete 

Updated the configurator to no longer allow 400 Hz for any BL breakers. 

Technical Info

  • KB Version: 00.00.07.01 

  • Price Version: 20230701

  • Release Date: 09/2023


PowerMod.

New PowerMod Modules with 3VA Mains or Tenant Breakers are being launched - See list below: (ref. BTKB-107)

  1. WEBV:   200-600A – EUSERC Mains (85kA & 100kA)

  1. WBTV:   200-600A – Feed-Thru Mains (85kA & 100kA)

  1. WMKV:  200-600A – Commercial Stacks (upgraded to 65kA max IR)

  1. WMLV:  200-400A – Commercial Stacks (upgraded to 85kA max IR)

  1. WBV:     700-800A – Standard Mains (85kA & 100kA)

  • The new Devices will replace the previous series Sentron based WEB, WBT, WMK, WML and WB series.

Legacy Sentron product will be available for printing layouts only – all new orders will be WxV or WxxV series.

  • The new 3VA based WxV and WxxV series is generally in 85 kA & 100 kA only (3VA53 400A max. and 3VA54 600A max.)

Users must select 85, 65 or 100 kA in order to get a list of available WxV or WxxV units. (65kA or less is typ. for Sentron Wx/Wxx)

  • When a Sentron series catalog is selected an error message will be shown advising to change to the “…V” series.

  • There may be a small difference in the Enclosure sizes – these are reflected in the layouts.

  • Additional Defaults are being established for various Power Mod Types to reduce the typical number of “clicks” needed to configure a product.

These are being introduced as we introduce the new 3VA breakers into Power Mod.

  • This process of adding defaults may take additional releases to complete all updates to all Power Mod types of products.

Technical Info

  • KB Version: 00.00.28.01

  • Price Version: 20220701

  • Release Date: 09/2023

.


Panelboard.

. .

  • Removed discontinued VB switches from Panelboard KB

  • Send configurations with Sentron DAS to TR

  • Conflict P2 panels with 3VA41 main with copper lugs and 200% neutral

  • Remove ASCO 911, 920 from Panelboard configurator as they have been discontinued

  • Change selections for 3VA metering to be more informative

  • Restrict 3VA41 MEAB, HEAB in 600/347 3PH WYE AC RP1 Panels

  • calculate the poles for SEM 3 per section and not all sections together

  • Change NEC selection at Panelboard level to be 2023 NEC215.15 Barrier

  • Fix issue with unit space to allow the addition of appropriate number of GFCI breakers

Technical Info

  • KB Version: 01.01.96.05

  • Price Version: 20230905

  • Release Date: 09/2023

.


Safety Switch.

  • Heavy Duty & Heavy Duty – Solar Disconnect and General Duty 400/600 Amp Rated - Fusible:

    • Class R Fuse Clip Kit - 400 Amp - HR656A was HR HR65A

    • Class R Fuse Clip Kit - 600 Amp - HR656A was HR HR66A

  • General Duty   30 Amp - LF versions not available with Line Side Internal Shield

  • General Duty 400/600 Amp - text message added to indicate Line Side Internal Shield provided as standard

Technical Info

  • KB Version: 00.00.03.01 

  • Price Version: 20230701

  • Release Date: 09/2023


Switchboard.

3WA:

  • Phase 1 release. Frame size 2 & 3 only. Accessories will need to be manually reselected when changing from WL to 3WA

MCCB:

  • Allow solid state trip MCCBs to be SB1, instead of SB2

  • 38 & 40W 3VA drawing issues (BTKB-275)

  • Correct 2P GFCI front views

Section:

  • Correct total assembly time errors

  • 11-D-0691 & 11-D-0394 front cover lines are incorrect (CK-4351)

  • Update 3000A ATS section dimensions (BTKB-296)

Switchboard:

  • Update Sm@rtgear selections & default breaker communications to Profinet

  • Add 90C bussed wireway for Canada configurations only

  • Require rear access when ATS 3000A & greater (BTKB-296)

Technical Info

  • KB Version: 01.01.72.02

  • Price Version: 20230701

  • Release Date: 09/29/2023