This articles details the information on the features and bug fixes released as part of COMPAS knowledge base. Following are released for the month of February 2022.
Switchboard
|
MCCBs
|
|
- Add 3VA handle extension selection & pricing
|
|
- Prevent 3VA test device power supply when TD-300 selected
|
|
- Update 400/600A load lug selections
|
|
- Revise 3VA front view drawing to match cover plate design
|
|
- Add conflict & tech review when non-3VA panel mounted 400/600A MCCB is selected
|
|
- Prevent new configurations and add conflict during reconfiguration of quotes containing 150/250A VLs
|
|
- Add 3VA ST voltage to the estimate sheet key description (CK-3642)
|
|
- Remove ‘Legacy conflict’ when BU region = Canada
|
|
|
|
Switchboard
|
|
- Update order routing for USS to E170
|
|
- Add option code & lead time identifier for Russelectric ATS
|
|
- Correct conflict when 70H WL tie section with auxiliary metering
|
|
- Prevent 25W WL section when NYC code
|
|
- Set minimum depth to 48” when hoist & track + Busway connections
|
|
- Correct missing electrical view for 800A panel mounted HCP main
|
|
- 11-D-0517 with Compression lugs should be SB3 (CK-704)
|
|
|
|
SMM
|
|
- Prevent adding SMMs when utility is Seattle City & Light
|
|
|
|
Utility Metering
|
|
- Allow GA Power @ 38W, with tech review required
|
|
- Add front view drawing support for 30.88” & 35.88” H utility doors (Canadian utilities)
|
|
- Correct issue with cold sequence utility drawings
|
|
- Correct issue with load lugs not showing on utility electrical view
|
|
- Change Canada utilities hinge side to right
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
Siebreak
|
NO TECH REVIEW:
|
|
|
|
|
|
|
|
|
|
|
|
- Blown fuse indication (no shunt trip)
|
|
|
|
TECH REVIEW REQUIRED:
|
|
|
|
- LIS with shunt trip or shunt close
|
|
|
|
|
|
- Any custom mods – at parent and/or child level
|
|
- Line ups with 4 or more units
|
|
|
|
Additional Updates:
|
|
- 3 kVA CPT option added for Rated Voltage of 5 kV [List price: $1810]
|
|
- “Light and switch” checkbox is selected as default for NEMA 3R enclosure type
|
|
- User can still manually choose to remove the selection
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
MCC
|
MCC Updates
|
|
- Added 125-250A 3VA circuit breaker to FCB units.
|
|
- 600V MM440 VFD is no longer allowed.
|
|
- 18 Pulse VFD is no longer allowed.
|
|
- G120 PM240-2 VFD B frame with 2 contactors is now a unit height of 24 for CED breaker.
|
|
- Added short circuit rating of 480V 100K for CED6 thermal magnetic breaker with size 4 heavy duty contactor.
|
|
- Changing Assemble to Order from true to false no longer sets all pilot device quantities from 1 to blank.
|
|
- Added Wiring Diagram value Special Unique and new characteristics Special Unique Unit Diagram 1 - 4.
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
Components
|
Transformer
|
|
- Updated to have Series F as the Default Series for 3F3Y 480:208Y 15-750 KVA , Aluminum Wound, Temperature Rise 80C/115C .
|
|
- Series A was the Default Series and is now an available alternative series for these versions.
|
|
|
|
Technical Info
|
|
|
|
|
|
|
|
|
|
WL Breaker
|
|
- Updated for the correct pricing key value for WL Breakers with a combination of Communication = PROFINET IO/MODBUS TCP (COM35) and Remote Close Switch 120VAC.
|
|
|
|
Technical Info
|
|
|
|
|
|
|
|
|
|
Pumppanel/Pump Controllers
|
|
- Dynamic Cut Sheets now available in COMPAS GO for TYZ:Pumppanel Class 83/84/87/88 with Factory Modifications.
|
|
|
|
Pump Controllers Class 83 & 84
|
|
- NEMA 12/3/3R now meets NEMA 12/3/3R/4. NEMA 4 painted now obsolete.
|
|
- Coil Description 120 VAC Separate Control changes to 120V 60 Hz/110 VAC 50 Hz
|
|
- Coil Description 24 VAC Separate Control changes to 24V 50-60 Hz
|
|
- Obsolete factory mod SC Surge Capacitor
|
|
- Factory mods R22, R40, G22 updated from 3RH1 to 3RH2 versions
|
|
|
|
Pump Panel Class 87
|
|
- Coil Description 120 VAC Separate Control changes to 120V 60 Hz/110 VAC 50 Hz
|
|
- Coil Description 24 VAC Separate Control changes to 24V 50-60 Hz
|
|
- Vacuum Contactor versions are now 600 VAC rated with a ‘6’ in the catalog number. Previous versions were 480 VAC rated with a ‘4’ in the catalog number. Please see the Speedfax or Industrial Catalog for more details.
|
|
- Obsolete factory mod SC Surge Capacitor
|
|
- Factory mods R22, R40, G22 updated from 3RH1 to 3RH2 versions
|
|
|
|
Pump Panel Class 88
|
|
- Coil Description 120 VAC Separate Control changes to 120V 60 Hz/110 VAC 50 Hz
|
|
- Coil Description 24 VAC Separate Control changes to 24V 50-60 Hz
|
|
- Obsolete factory mod SC Surge Capacitor
|
|
- Factory mods R22, R40, G22 updated from 3RH1 to 3RH2 versions
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
Panelboard
|
Panelboard Updates
|
|
- Implement 3VA55/65/66 lug restrictions for Skinny P5
|
|
- Correct import issue in ECR for P4
|
|
- Prevent VL DG/FG frames in new configurations and select tech review required for existing configurations
|
|
- Correct issue where 3VA66 lug catalog number was not populating
|
|
- Correct conflict when creating series rated configurations
|
|
- Correct conflict when 3VA65 @ 800A with 100% rating
|
|
- Add conflict message when 3VA66 with 100% rated
|
|
- Correct issue with FTL position shifted up when configuring 3VA under split bus
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
Russelectric
|
Russelectric ATS
|
|
Power Connections
|
|
- 2P standard mechanical lug ranges added
|
|
Complexity
|
|
- Show Engineering complexity at top of window. Changes dynamically with configuration selections
|
|
Switch Configuration
|
|
- RPTCS controller enabled for manual operation switches
|
|
|
|
Russelectric ATS Mods
|
|
Complexity
|
|
- Show Engineering complexity at top of window. Changes dynamically with configuration selections
|
|
|
|
Russelectric LV/MV SWG
|
|
WL Breaker
|
|
- Fixed bug with Cradle catalog number not populating for some configurations
|
|
Comp. Breaker
|
|
|
|
System
|
|
- Remove System Interrupt Rating and replaced with Bus rating
|
|
|
|
Technical Info
|
|