This article details the information on the features and bug fixes released as part of COMPAS knowledge base. Following are released for the month of August 2022.
.
Switchboard
|
3VA Breakers
|
|
- Update 600AF 3VA 100% rated lugs to default to CU lugs (CK-3981)
|
|
- Correct pricing issue with 3VA communications when
|
|
|
|
Drawings
|
|
- Correct electrical view for 3VA IPS Main (CK-3982)
|
|
- Add new symbols to advanced editing view (CK-3982)
|
|
- Add 1.5” & 4.0” CA channel sills (CK-3966)
|
|
|
|
Configuration
|
|
- Add warning when use existing DAS compartment selected
|
|
- Add IR window selections (CK-3952)
|
|
- Correct width for 3VA52 w/SEM3 (CK-3935)
|
|
- Select pull box when BPS combo with top load busway connection (CK-3971)
|
|
|
|
Pull Section
|
|
- Add 48W dominion power pull section width and bussed utility width (CK-3988)
|
|
|
|
Proposal
|
|
- Update to show lightning arrestor on proposal and estimate sheet
|
|
|
|
Service Section
|
|
- Add 11-D-0697 from 1E-458B (ss 3VA cable feed main panel)
|
|
|
|
Switchboard
|
|
- Add selections for IR windows (CK-3951)
|
|
- Correct error with right feed thru bus continuity tech review (CK-3987)
|
|
- Updates for CA channel sills (CK-3966)
|
|
- Add functional costing for CA FP MCCB (CK-3985)
|
|
|
|
|
|
WL
|
|
- Add selection + price adder for WL yolk, when draw-out mount (CK-3984)
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
SIEBREAK
|
MODIFICATIONS TO AUXILIARY UNITS
|
|
- Added checkboxes for the following options, each of which will trigger LV Compartment:
|
|
|
|
|
|
|
|
|
|
-
- CT Short Circuiting Terminal Block
|
|
- Added Digital Metering “Device” tab
|
|
-
- The presence of any digital metering configuration will also trigger LV Compartment
|
|
|
|
MODIFICATIONS TO LIS UNITS
|
|
- In addition to existing rules, the following selections will now trigger LV Compartment:
|
|
|
|
|
|
|
|
|
|
|
|
-
- CT Short Circuiting Terminal Block
|
|
|
|
MODIFICATIONS TO VCB UNITS
|
|
- Default for “2NO+2NC auxiliary switch” is now TRUE (selected checkbox)
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
Russelectric
|
Russelectric ATS
|
|
Switch Information
|
|
- Remove obsolete voltage ratings for RTSCD
|
|
|
|
Russelectric ATS Mods
|
|
Field Service
|
|
- Default travel rate increased to $270
|
|
|
|
Russelectric LV/MV/CNTRL SWG
|
|
Enclosure Options
|
|
- Lift devices split into separate selections w/ pricing. Multiple lift devices can be applied to one line up of switchgear
|
|
|
|
Russelectric SWG Mods
|
|
Field Service
|
|
- Default travel rate increased to $270
|
|
|
|
Technical Info
|
|
- KB Version: Russelectric ATS [00.00.16.01], Russelectric ATS Mods [00.00.16.01], Russelectric LV/MV/CNTRL SWG [00.00.14.01], Russelectric SWG Mods [00.00.13.01]
|
|
|
|
|
.
Components
|
Molded Case Circuit Breaker
|
|
- Added 3VA Breaker – Trip Unit Types : Molded Case Switch and Motor Circuit Protector (Magnetic Only ETI)
|
|
- Updated Line Side and Load Side Lug options for 100% Rated Breakers
|
|
|
|
Safety Switch
|
|
- General Duty Switches – Corrected Neutral option for Fusible 30A and 60A versions.
|
|
- General Duty Switches – Corrected Ground Lug Kit for 30A and 60A versions with Oversized Enclosures.
|
|
|
|
Technical Info
|
|
- KB Version: Molded Case Circuit Breaker [00.00.00.53], Safety Switch [00.00.00.14]
|
|
|
|
|
.
Panelboard
|
- CK-3783: 3VA Comm. Compartment availability for P2 & P3
|
|
- CK-3853: SAP Cstic for Breaker Family
|
|
- CK-3977: Automatic gutter space generation when meter is added
|
|
- CK-4028: Expansion module for comms should be selectable only at top level
|
|
- CK-4029: Ability to select expansion module for 3VA main breaker
|
|
- CK-4030: Call out COM800 for 2-8 breakers or COM100 for 1
|
|
- CK-4031: Show Comm compartment when comm modules are ordered
|
|
- CK-4032: Allow Comm module for 3VA6 only when LCD is picked.
|
|
- CK-4033: 3VA defaults added on Panel board level configuration
|
|
- CK-4034: PROFINET expansion module added for P2, P3 and P5 as an option
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
PowerMod
|
New WBV 200-600A Breaker Mains
|
|
- WBV features 3VA molded case circuit breakers
|
|
|
|
- Standard Main, Skinny Main, and Blank End Wall (No hubs) options all available
|
|
- Standard Mains have provision for field installed BSPD Surge Protection device (w/ECBSPDV3 field mount kit)
|
|
- New Lug Landing Pad for use with Standard WBV: LLPV600
|
|
- Replaces 200-600A WB breaker mains (Sentron MCCB)
|
|
- WBs can no longer be configured in COMPAS PowerMod configurator
|
|
- WBs can still be ordered for a limited time as standard product in COMPAS
|
|
|
|
WSPD Surge Protection Modules
|
|
- Modify catalog number (3VA) for factory installed Breaker Disconnect on Standard Modules (was HEG)
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
LVS / RCS
|
Digital Metering
|
|
- Remove PAC3100 and PAC3200 meters
|
|
- Correct pricing keys for PAC3220 and PAC4200 expansion modules
|
|
- Modify user interface to consolidate 5 tabs into 1
|
|
|
|
Wire Points
|
|
- Custom component wire points sum into section wire points
|
|
- Correct wire point values for Digital Meters and DM accessories.
|
|
|
|
Technical Info
|
|
|
|
|
|
|
.
MCC
|
- Changed from LG breaker to CED6 breaker for VFD 65K 480V G120C 5-10HP high overload and G120 7.5-15HP high overload.
|
|
- PFCC unit TFNM, TFPM Myron Zucker capacitors are obsolete and are replaced by TFNX, TFPX Myron Zucker capacitors which affects PFCC unit sizing.
|
|
- FCB WL circuit breaker is no longer yellow and is now green.
|
|
- MCC level characteristics General Notes Line 1, General Notes Line 2, Shop Notes Line 1, Shop Notes Line 2 now appear on drawing general specification for MCC Unit Only.
|
|
- Added unit oversizing rules for ASI master unit and removed AE required technical review. Added 192VA for CPT demand VA for ASI power supply.
|
|
- ASI master unit when unit size is specified now allows all panel types not just 15 wide and hat shaped.
|
|
- Added Detail A, B, C, D to SPD wiring diagram D68500TV2.
|
|
- Drawing details tab Incoming spec now generates data for two incomings with sub feed MLO.
|
|
- Can now specify 2S1W, 2S2W low speed and high-speed KW units like HP units.
|
|
- Disallowed elapsed time meter in 6-inch-high density unit.
|
|
- No longer able to add a meter unit from a MCC space unit. No longer able to add an option from a MCC unit only space unit.
|
|
- Added notes T4 - stationary power terminal blocks are provided for starter units through size 3. power terminal blocks are not provided for larger sizes.
|
|
- T5 - screw stationary power terminal blocks are provided for starter units through size 3. power terminal blocks are not provided for larger sizes.
|
|
- Added characteristic Option Code to drawing details Layout tab for COMPAS OE config xml.
|
|
|
|
Technical Info
|
|
|
|
|
|
|